views
Installation position of LED fire exit signs
1. enclosed stairwells, smoke-proof stairwells and their front rooms, fire-fighting lifts and their front rooms.
2. power distribution rooms, fire control rooms, automatic generator rooms, fire pump rooms, smoke and smoke control rooms, battery rooms for fire-fighting electricity, telephone switchboard rooms and other rooms where it is necessary to remain in the fire environment to extinguish the fire in the event of a fire.
3. exhibition halls, business halls with an auditorium of more than 1500 m² per floor, studios with a floor area of more than 2000 m², basements with a dense population and a floor area of more than 300 m², etc.
4. evacuation aisles (safety exit routes) and internal aisles exceeding 20 metres in length in public buildings, etc.
Installation specifications for LED fire exit signs
LED fire emergency exit signs can be divided into safety exit signs and evacuation channel indication signs.
(1) The installation position of the safety exit sign light is usually at the exit of the normal exit and emergency passage leading to the outdoors in the building. Multi-storey and high-rise building each floor to the stairwell and fire lift front room door; large area of the hall, field, hall to the evacuation channel and the exit to the vestibule, side hall, stairwell; safety exit sign light is generally installed in the exit door frame above, if the door frame is too high, can be installed in the door frame of the side entrance position; in order to prevent the smoke generated when the fire occurs affect the visual, its installation height to 2.2-2.5 m is appropriate.
(2) The installation position of the fire safety indicator is usually in the safety evacuation channel of the public building, so that when people evacuate, they can find the correct emergency exit no matter which position they are in, and the spacing of the emergency evacuation indicator installed in the fire emergency evacuation channel or safety emergency exit channel should not be greater than 20 metres.
(3) The frontal screen part of the safety exit indicator should be kept at a vertical angle to the safety evacuation channel as far as possible.
EFFORT Semiconductor Lighting Ltd. focuses on the field of LED emergency lighting, producing and selling emergency lighting products such as LED fire emergency exit signs. If you need it, you can contact us, call +86-0574-27693030, email Sales@effortled.com or log on to https://www.effortempro.com/.